Journal of Northeastern University ›› 2004, Vol. 25 ›› Issue (4): 360-362.DOI: -

• OriginalPaper • Previous Articles     Next Articles

Simulation on temperature field under ultra fast cooling

Peng, Liang-Gui (1); Liu, Xiang-Hua (1); Wang, Guo-Dong (1)   

  1. (1) Lab. of Rolling and Automat., Northeastern Univ., Shenyang 110004, China
  • Received:2013-06-24 Revised:2013-06-24 Online:2004-04-15 Published:2013-06-24
  • Contact: Peng, L.-G.
  • About author:-
  • Supported by:
    -

Abstract: Temperature field under ultra fast cooling (UFC) is simulated by finite-difference method. The results show that when a slab which was rolled from 180 mm to 40 mm by 6 passes at an initial temperature 1200°C enters into a UFC zone standing between the roughing mill and finishing mill at 3 m/s, a water cooling rate 70°/s can be obtained if the heat-exchange coefficient is up to 10 kW/(m2·°C). At the same time, the entrance finishing temperature must be corrected because of the strong temperature recovery after UFC.