  1. (1) School of Materials and Metallurgy, Northeastern University, Shenyang 110819, China; (2) Department of Building Science, Tsinghua University, Beijing 100084, China; (3) Beijing Laboratory of Heating, Gas-Supply, Ventilation and Air-Conditioning, Beijing Institute of Civil Engineering and Architecture, Beijing 100044, China
  • Received:2013-06-19 Revised:2013-06-19 Published:2013-04-04
  • Contact: Han, Z.-W.
  • About author:-
  • Supported by:
    -

摘要: 针对寒冷地区长期应用地源热泵系统出现的热平衡问题,提出了季节性蓄存环境空气热能的地源热泵供暖空调系统.介绍了该系统的组成及运行模式,建立了系统中各部分的数学模型,确定了系统的运行控制策略,并在此基础上,以哈尔滨地区某办公建筑为对象进行了瞬态数值模拟.由模拟结果可知,该系统能够保持土壤温度场以年为周期的热平衡,全年供暖空调平均性能系数为2.44,与燃煤锅炉供暖和分体空调供冷方案相比,该系统节能率为22.3%.

关键词: 土壤热平衡, 地源热泵, 季节性蓄存空气热能, 数值模拟, 性能系数

Abstract: Regarding the problem of ground heat balance in cold area, a ground source heat pump system which can seasonally accumulate environmental air thermal energy was presented. The components and operation modes of the system were introduced, and the control strategy of system operation was determined through setting up the mathematic model of each system section. Based on the mathematic model and control strategy, the transient numerical simulation was carried out for an office building in Harbin. The simulation results show that the ground source heat pump system can retain thermal balance of the soil temperature field over an one year cycle. The average coefficient of performance was calculated to be 2.44. Compared with that of the coal-fired heating and air conditioning, the system energy-saving rate is 22.3%.