Journal of Northeastern University Natural Science ›› 2015, Vol. 36 ›› Issue (6): 832-837.DOI: 10.12068/j.issn.1005-3026.2015.06.017

• Mechanical Engineering • Previous Articles     Next Articles

A Calibration Method on Base Excitation Amplitude of Piezoelectric Ceramic Exciter

LI Hui, LIU Ying, WANG Yu, SUN Wei   

  1. School of Mechanical Engineering & Automation, Northeastern University, Shenyang 110819, China.
  • Received:2014-03-13 Revised:2014-03-13 Online:2015-06-15 Published:2015-06-11
  • Contact: LI Hui
  • About author:-
  • Supported by:
    -

Abstract: This paper researched how to accurately obtain base excitation amplitude of piezoelectric ceramic exciter (PCE) by some calibration methods. Firstly, a simple and reliable calibration method was proposed. The dynamics model of cantilever beam under base excitation of PCE was established to clarify calibration principle and simulate calibration process. Next, the calibration and test system of base excitation amplitude of PCE was set up. The key steps of this method were explained in details. At last, practicability and effectiveness of above calibration method were demonstrated by experiment.

Key words: base excitation, piezoelectric ceramic exciter (PCE), excitation amplitude, calibration method

CLC Number: