东北大学学报:自然科学版 ›› 2017, Vol. 38 ›› Issue (9): 1230-1234.DOI: 10.12068/j.issn.1005-3026.2017.09.004

• 信息与控制 • 上一篇    下一篇

中心动脉与肱动脉参数的相关性及其回归分析

徐礼胜, 柴蕊, 姚阳, 张欠欠   

  1. (东北大学 中荷生物医学与信息工程学院, 辽宁 沈阳110169)
  • 收稿日期:2016-04-05 修回日期:2016-04-05 出版日期:2017-09-15 发布日期:2017-09-08
  • 通讯作者: 徐礼胜
  • 作者简介:徐礼胜(1975-),男,安徽安庆人,东北大学教授,博士生导师.
  • 基金资助:
    国家自然科学基金资助项目(61374015,61202258); 中央高校基本科研业务费探索导向重点资助项目(N161904002,N130404016).

Correlation and Regression Analysis on the Parameters of Central Aortic and Brachial Pulse Waves

XU Li-sheng, CHAI Rui, YAO Yang, ZHANG Qian-qian   

  1. School of Sino-Dutch Biomedical & Information Engineering, Northeastern University, Shenyang 110169, China.
  • Received:2016-04-05 Revised:2016-04-05 Online:2017-09-15 Published:2017-09-08
  • Contact: XU Li-sheng
  • About author:-
  • Supported by:
    -

摘要: 探讨中心动脉与肱动脉舒张压(DBP)、收缩压(SBP)、脉压(PP)、心内膜下心肌活力率(SEVR)、波形参数(k)、每搏输出量(SV)、心排量(CO)、外周阻力(RS)等参数的相关性.通过对40例临床需要进行冠状动脉造影患者的有创中心动脉参数与肱动脉参数进行相关分析,将直接测得的中心动脉参数分别与通过回归方程、建立模型估算的中心动脉参数进行配对t检验和Bland-Altman图示.结果表明:除k值外的所有中心动脉与肱动脉参数均相关;两种估算方法DBP,SEVR一致性相当,其回归方程用Y′=a+bx表示;DBP,SBP,PP,SEVR,SV,CO也可通过回归方程估算,但准确性比传递函数差.

关键词: 中心动脉参数, 肱动脉参数, 回归方程, 传递函数, 相关性

Abstract: This study mainly analyzed the correlation of the parameters such as diastolic blood pressure (DBP), systolic blood pressure (SBP), pulse pressure (PP), subendocardial viability ratio (SEVR), waveform parameter (k), stroke volume (SV), cardiac output (CO) and peripheral resistance (RS) of aortic pulse wave and brachial pulse wave invasively measured. Correlation analysis was performed on invasive central aortic parameters and brachial artery parameters of 40 patients who needed coronary arteriography. With the paired t-test and Bland-Altman method, these parameters extracted from the central pulse wave invasively measured were compared with the parameters of central aortic pulse wave caculated by a regression equation and a model. Results and conclusion: in addition to the k value, the above parameters of the central pulse wave and the brachial pulse wave invasively measured had positive correlation; DBP and SEVR had the same consistency in the two estimation methods, and the regression equations of the two parameters were expressed by Y′=a+bx. The DBP, SBP, PP, SEVR, SV, CO also can be calculated by the regression equation, but its accuracy is worse than that of the transfer function model.

Key words: parameters of central aortic pulse wave, parameters of brachial pulse wave, regression equation, transfer function, correlation

中图分类号: