Modeling Simulation of Upper Limb Vascular System Based on Fusion of Windkessel and Tube-Load Models
ZHOU Shu-ran1, YAO Yang1, HAO Li-ling1, XU Li-sheng1,2
1. School of Sino-Dutch Biomedical & Information Engineering, Northeastern University, Shenyang 110169, China; 2. Key Laboratory of Medical Image Computing, Ministry of Education, Northeastern University, Shenyang 110169, China.
ZHOU Shu-ran, YAO Yang, HAO Li-ling, XU Li-sheng. Modeling Simulation of Upper Limb Vascular System Based on Fusion of Windkessel and Tube-Load Models[J]. Journal of Northeastern University Natural Science, 2018, 39(3): 329-333.
[1]Frank O.Die grundform des arteriellen pulses[J].Zeitschrift für Biologie,1899,37(19):483-526. [2]Goldwyn R M,Watt T B.Arterial pressure pulse contour analysis via a mathematical model for the clinical quantification of human vascular properties[J]. IEEE Transactions on Biomedical Engineering,1967,14(1):11-17. [3]何为,余传祥.心血管动力学参数测量原理与临床应用[M].北京:科学出版社,2010:276-304.(He Wei,Yu Chuan-xiang.The measuring principle and clinical application of cardiovascular dynamics parameters[M].Beijing:Science Press,2010:276-304.) [4]Womersley J R.Oscillatory flow in arteries:the constrained elastic tube as a model of arterial flow and pulse transmission[J].Physics in Medicine & Biology,1957,2(2):178-187. [5]Ling S C,Atabek H B.A nonlinear analysis of pulsatile flow in arteries[J].Fluid Mechanics,1972,55(3):493-511. [6]Alastruey J,Khir A W,Matthys K S,et al.Pulse wave propagation in a model human arterial network:assessment of 1-D visco-elastic simulations against in vitro measurements[J].Journal of Biomechanics,2011, 44(12):2250-2258. [7]罗志昌,张松,杨益民.脉搏波的工程分析与临床应用[M].北京:科学出版社,2006:8-155.(Luo Zhi-chang,Zhang Song,Yang Yi-min.Engineering analysis and clinical applications of pulse wave[M].Beijing:Science Press,2006:8-155.) [8]王昊,伏全海,徐礼胜,等.基于血管弹性腔模型的脉搏波发生器的现场可编程门阵列设计与实现[J].生物医学工程学杂志,2014,31(5):989-993.(Wang Hao,Fu Quan-hai,Xu Li-sheng,et al.Design and implementation of the pulse wave generator with field programmable gate array based on windkessel model[J].Journal of Biomedical Engineering,2014,31(5):989-993.) [9]Liu H,Liang F,Wong J,et al.Multi-scale modeling of hemodynamics in the cardiovascular system[J].Acta Mechanica Sinica,2015,31(4):446-464. [10]Nguyen P,Kim J M.Adaptive ECG denoising using genetic algorithm-based thresholding and ensemble empirical mode decomposition[J].Information Sciences,2016,373(1):499-511. [11]Huotari M,Mtt K,Rning J.Photoplethysmographic measurements of arterial and aortic pulse waveform characteristics[J].Finnish Journal of Ehealth & Ewelfare,2015,7(2/3):83-87.