Beaforming Algorithm Based on Minimum Variance Delay Multiplication and Sum for Medical Ultrasound
SU Ting1,2, YAO Ding-jie1, LI Da-yu1, ZHANG Shi1
1. School of Computer Science & Engineering, Northeastern University, Shenyang 110169, China; 2. Department of Science, Anyang Institute of Technology, Anyang 455000, China.
SU Ting, YAO Ding-jie, LI Da-yu, ZHANG Shi. Beaforming Algorithm Based on Minimum Variance Delay Multiplication and Sum for Medical Ultrasound[J]. Journal of Northeastern University Natural Science, 2018, 39(4): 473-477.
[1]彭虎.超声成像算法导论[M].合肥:中国科学技术大学出版社,2008:118-120.(Peng Hu.Introduction to ultrasound imaging algorithm[M].Hefei:University of Science and Technology of China Press,2008:118-120.) [2]Asl B M,Mahloojifar A.Minimum variance beamforming combined with adaptive coherence weighting applied to medical ultrasound imaging[J].IEEE Transactions on Ultrasonics Ferroelectrics Frequency Control,2009,56(9):1923-1931. [3]Capon J.High-resolution frequency-wave number spectrum analysis[J].Proceedings of the IEEE,1969,57(8):1408-1418. [4]Hayashi H.Trend of weight reduction of automobile and expectation for aluminum alloys as light weight materials[J].Journal of Japan Institute of Light Metals,2005,55(8):371-376. [5]王平,许琴,范文政,等.超声成像中基于特征空间和前后向最小方差波束形成[J].声学学报,2013,38(1):65-70.(Wang Ping,Xu Qin,Fan Wen-zheng,et al.Eigenspace-based forward-backward minimum variance beamforming applied to ultrasound imaging[J].Acta Acustica,2013,38(1):65-70.) [6]刘振,孙超,刘雄厚,等.一种加权稀疏约束稳健Capon波束形成方法[J].物理学报,2016,65(10):1-9.(Liu Zhen,Sun Chao,Liu Xiong-Hou,et al.Robust Capon beamforming with weighted sparse constraint[J].Acta Physica Sinica,2016,65(10):1-9.) [7]Okumura S,Taki H,Sato T.High-contrast and low-computational complexity medical ultrasound imaging using beamspace Capon method[C]//37th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBS).Milan:IEEE,2015:6334-6337. [8]Synnevg J,Austeng A,Holm S.Adaptive beamforming applied to medical ultrasound imaging[J].IEEE Transactions on Ultrasonics Ferroelectrics Frequency Control,2007,54(8):1606-1613. [9]Chernyakova T,Eldar Y.Fourier-domain beamforming:the path to compressed ultrasound imaging[J].IEEE Transactions on Ultrasonics Ferroelectrics Frequency Control,2013,61(8):1252-1267. [10]Guenther D A,Walker W F.Robust FIR beamforming applied to medical ultrasound[J].IEEE Transactions on Ultrasonics Ferroelectrics Frequency Control,2009,56(6):1168-1188. [11]Matrone G,Savoia A S,Caliano G,et al.The delay multiply and sum beamforming algorithm in ultrasound B-mode medical imaging[J].IEEE Transactions on Medical Imaging,2015,34(4):940-949. [12]Matrone G,Savoia A S,Caliano G,et al.Ultrasound synthetic aperture focusing with the delay multiply and sum beamforming algorithm[C]//37th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBS).Milan:IEEE,2015:137-140. [13]吴文寿,蒲杰,吕燚.最小方差波束形成与广义相干系数融合的医学超声成像方法[J].声学学报,2011,36(1):66-72.(Wu Wen-shou,Pu Jie,Lyu Yi.Medical ultrasound imaging method combining minimum variance beamforming and general coherence factor[J].Acta Acustoca,2011,36(1):66-72.) [14]Jensen J A.FIELD:a program for simulating ultrasound systems[J].Medical & Biological Engineering & Computing,1999,34(1):351-353. [15]O′Donnell M,Flax S W.Phase-aberration correction using signals from point reflectors and diffuse scatterers:measurements[J].IEEE Transactions on Ultrasonics Ferroelectrics Frequency Control,1988,35(6):768-774. [16]Krishnan S,Rigby K W,O′Dolmell M.Improved estimation of phase aberration profiles[J].IEEE Transactions on Ultrasonics Ferroelectrics Frequency Control,1997,44(3):701-713. [17]Lok U W,Li P C.Transform-based channel-data compression to improve the performance of a real-time GPU-based software beamformer[J].IEEE Transactions on Ultrasonics Ferroelectrics Frequency Control,2016,63(3):369-380.